STUDIES ON THE PROVISIONS OF CONFINING-REINFORCEMENT FOR HIGH-STRENGTH CONCRETE COLUMN

view full text

Abstract

It is general knowledge that the design of earthquake-resistant structures for high-strength concrete columns requires confining-reinforcement with a relatively high volumetric ratio to ensure the ductility of the structure. This implies that the mechanical behavior of high-strength concrete differs significantly from the behavior of normal-strength concrete. However, the provisions on the minimum volumetric ratio of confining-reinforcement contained in the Indonesian Concrete Code (SNI 2847-2013) is essentially derived from the test results for normal-strength concrete. This paper studies the confining- reinforcement provisions used in several standards, i.e., SNI 2847-2013, ACI-2011, NZS-2006 and CSA-2004, to determine the ductility of the concrete columns. The case study is based on the analysis of the cross-section of high-strength concrete columns, the parameters that affect the strength, and by evaluating the value of the column’s cross-section curvature ductility. The study results showed that the equation for confining-reinforcement adopted in the SNI 2847-2013 is very conservative compared to other codes when applied to low axial load levels (≤0.2), but is relatively less conservative if the axial load level is greater than 0.3. 

Keywords: high-strength concrete, column, confinement, reinforcement, ductility

Nama Prosiding : Proceedings of the 2nd SCESCM. International Conference on Sustainable Civil Engineering Structures and Construction Materials (SCESCM)
ISSN :
Tahun : 2014
Peneliti : Antonius,,
Diunggah tanggal : Kamis, 2014-10-30